LZQ is an OEM factory for all kinds of dental implant screwdrivers, such as hand driver, machine driver, handpiece driver, abutment drive, internal hex drivers, external hex drivers, slot driver, star driver, Torx driver, square driver, Octa abutment driver, ratchet implant driver, torque driver, tap driver contra-angle driver, short driver, medium driver, long driver and stainless steel driver, ect.

Manual Driver for screw implants
LZQ is an OEM factory for all kinds of dental implant screwdrivers, such as hand driver, machine driver, handpiece driver, abutment drive, internal hex drivers, external hex drivers, slot driver, star driver, Torx driver, square driver, Octa abutment driver, ratchet implant driver, torque driver, tap driver contra-angle driver, short driver, medium driver, long driver and stainless steel driver, ect. We can produce a whole kit of tools for customers’ surgical cases.
We use the material of stainless steel.
We are capable to produce any size and shape of dental implant drivers according to drawings or samples provided by customer with a favorable cost-performance.
Products Description
Manual adaptor for driver
Type: hand or machine
Connection: ratchet, torque wrench, solid abutment, handpiece, closure screws, fixture and healing caps (extra short, short, medium, long, extra long); different shapes and sizes of head are also available, such as internal hex, external hex, star, Torx, Octa, square, ect. Compatible with most dental implant products globally available now
Different functions of different types:
1. Torque driver connection, to adjust the retention force.
2. ratchet wrench connection, for extension of simple mount length, and use in case of inputting hand-torque.
3. Fixture connection, to place or remove a fixture after the separation of the mount.
4. Handpiece connection, for screwing the implants into place.
5. Tip holding function: stopper designed for the prevention of fracture of the holding part and occurrence of foreign matter such as blood stain during surgery
6. Removing broken screws, this tool should be used together with the guide for each system. When the marked part of the reverse drill is exposed above the guide, connected to the fixture, make use of the screw-holder to remove the broken Screws
7. Connector used for connecting the driver for square torque to the round torque wrench.
To manually tighten fixing screws, to close abutment. To tighten all kind of implants. Safeguard maximum torque to avoid possible fracture. Some with diverging hex for better screw tightening and transport; Handling cover screws for Implants and Healing Cap.
Grooves, laser mark and color ring: designed for checking during the connection, can be customized according to your specific requirement.
Coating: can also be done if you need.
Heavy duty with robust design and proven material, complete solution for critical problems which might occur in the prosthetics process
Material / Characteristics
Application domain: for dental implantology
Material:
UNS S42000
(Super-high rust-proof stainless steel A+) (hardened HRC60°±2°Section)
Ultra-high anti-rust, high-sharpness and super-high wear-resistant stainless steel, with super-high wear resistance (super high hardness) performance and high standards of rust and corrosion resistance. It has a service life of 2 ~ 3 times longer than that of general stainless steel. The cutting edge keeps for a super-long time of cutting sharpness. Unmarked, with 5% Neutral salt spray test (ASTM B117), it doesn't rust after 300 hours, which meet FDA high standard. If for repeated use, it is recommended to clean and dry it in time after every surgery.
Wide range of applications. With excellent abrasion resistance and sharpness, it can be used to produce extremely complex, high-precision handle shapes and formed super-sharp edge structures.
. ASTM440PH . Type 440C
. UNS S44004PH . ASTM F899:
(Ultra-high rust-proof stainless steel AA) (hardened HRC54 ° ± 2 ° Section)
Ultra-high anti-rust & high wear-resistant , high hardness, high impact, high toughness stainless steel, with excellent anti-rust capability, corrosion resistance, wear resistance (high hardness) performance and ideal impact resistance.. Its excellent corrosion resistance is comparable to TYPE 304 Stainless steel; and its rust resistance is closer to alloy for surgical implant. Unmarked, with 5% Neutral salt spray test (ASTM B117), it doesn't rust after 1000 hours. Wide range of applications, quite good and stable quality, which can be used to produce extremely complex, high-precision shank shapes and profile ultra-sharp edge structures.
Applied for high-end medical standard: AMS 5936 . MMPDS-01 . ASTM A693 . ASTM A564 . ASTM F899-12
The Vitro (cytotoxicity) test verifies that the material does not have any potential cytotoxicity and therefore can safely contact human tissue, body fluids or blood, and meets all relevant allergy and skin irritation test standards.
Get a quote now
Fill this form and we\'ll get back to you soon.
Technical Documents
SHANGHAI LZQ PRECISION TOOL CO., LTD has nearly 30 years of rich experience in production and mature process details-micro-processing to achieve the ultimate product quality, which has Ultra-high Corrosion & Rust Resistance, Ultra-sharp Cutting Edge, Ultra-long Sharpness Retention Time, High Service Life and High Wear Resistance,
Navigation
Navigation
Conatct Us
Mob: +86 187 2171 9909 / +86 156 1823 8306
E-mail: zq@50323322.com
WeChat: +86 187 2171 9909 / +86 156 1823 8306
WhatsApp: +86 187 2171 9909 / +86 156 1823 8306
Add.: No. 1269 Jinhu Road, Jinqiao Export Processing Zone, Pudong, Shanghai
Send Inquiry
Send Inquiry